Energos: Use Record Formats to define energy analysis data: Difference between revisions
No edit summary |
No edit summary |
||
Line 29: | Line 29: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Field name !! Unit !! Description | ! Field name !! Unit !! Description !! .vwstring key | ||
|- | |- | ||
| Sort Index || Integer || Index used to order the elements | | Sort Index || Integer || Index used to order the elements || FieldInt_SortIndex | ||
|- | |- | ||
| Name || Text|| | | Name || Text|| || FieldText_Name | ||
|- | |- | ||
| Area || Number|| Area value in document units | | Area || Number|| Area value in document units || FieldDim_Area | ||
|- | |- | ||
| UValue || Number || U - value in document units | | UValue || Number || U - value in document units || FieldReal_UValue | ||
|- | |- | ||
| Orientation || Integer || Orientation values:<br/> | | Orientation || Integer || Orientation values:<br/> | ||
Line 48: | Line 48: | ||
6 - West<br/> | 6 - West<br/> | ||
7 - NorthWest<br/> | 7 - NorthWest<br/> | ||
8 - Horizontal | 8 - Horizontal || FieldInt_Orientation | ||
|- | |- | ||
| Inclination || Integer || Orientation inclination degrees:<br/> | | Inclination || Integer || Orientation inclination degrees:<br/> | ||
Line 62: | Line 62: | ||
9 = 150<br/> | 9 = 150<br/> | ||
10 = 165<br/> | 10 = 165<br/> | ||
11 = 180 - Horizontal | 11 = 180 - Horizontal || FieldInt_OrientInclination | ||
|- | |- | ||
| Reduction Factor Shading || Number || | | Reduction Factor Shading || Number || || FieldReal_ReductionFactorShading | ||
|- | |- | ||
| Wall Type|| Integer || <br/> | | Wall Type|| Integer || <br/> | ||
0 - Exterior Ambient<br/> | 0 - Exterior Ambient<br/> | ||
1 - Exterior Ground<br/> | 1 - Exterior Ground<br/> | ||
2 - Partition To Neighbour | 2 - Partition To Neighbour || FieldInt_WallType | ||
|} | |} | ||
Line 80: | Line 80: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Field name !! Unit !! Description | ! Field name !! Unit !! Description !! .vwstring key | ||
|- | |- | ||
| Sort Index || Integer || Index used to order the elements | | Sort Index || Integer || Index used to order the elements || FieldInt_SortIndex | ||
|- | |- | ||
| Name || Text|| | | Name || Text|| || FieldText_Name | ||
|- | |- | ||
| | | Quantity || Integer || || FieldLong_Quantity | ||
|- | |- | ||
| Location || Integer || Location values:<br/> | | Location || Integer || Location values:<br/> | ||
Line 94: | Line 92: | ||
1 - Ambient<br/> | 1 - Ambient<br/> | ||
2 - Perimeter<br/> | 2 - Perimeter<br/> | ||
3 - Floor/Slab | 3 - Floor/Slab || FieldLong_Location | ||
|- | |- | ||
| Length || Number || thermal bridge length in document units | | Length || Number || thermal bridge length in document units || FieldDim_Length | ||
|- | |- | ||
| PSI || Number || | | PSI || Number || || FieldReal_PSI | ||
|} | |} | ||
'''Note:''' strings are localizable via 'FormatDef_ThermalBridge.vwstrings' of the EnergyAnalysis.vwr | '''Note:''' strings are localizable via 'FormatDef_ThermalBridge.vwstrings' of the EnergyAnalysis.vwr | ||
Line 114: | Line 112: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Field name !! Unit !! Description | ! Field name !! Unit !! Description !! .vwstring key | ||
|- | |- | ||
| Sort Index || Integer || Index used to order the elements | | Sort Index || Integer || Index used to order the elements || FieldInt_SortIndex | ||
|- | |- | ||
| Name || Text || | | Name || Text || || FieldText_Name | ||
|- | |- | ||
| Area || Number || Area value in document units | | Area || Number || Area value in document units || FieldDim_Area | ||
|- | |- | ||
| UValue || Number || U - value in document units | | UValue || Number || U - value in document units || FieldReal_UValue | ||
|- | |- | ||
| Orientation || Integer || Orientation values:<br/> | | Orientation || Integer || Orientation values:<br/> | ||
Line 133: | Line 131: | ||
6 - West<br/> | 6 - West<br/> | ||
7 - NorthWest<br/> | 7 - NorthWest<br/> | ||
8 - Horizontal | 8 - Horizontal || FieldInt_Orientation | ||
|- | |- | ||
| Inclination || Integer || Orientation inclination degrees:<br/> | | Inclination || Integer || Orientation inclination degrees:<br/> | ||
Line 147: | Line 145: | ||
9 = 150<br/> | 9 = 150<br/> | ||
10 = 165<br/> | 10 = 165<br/> | ||
11 = 180 - Horizontal<br/> | 11 = 180 - Horizontal<br/> || FieldInt_OrientInclination | ||
|- | |- | ||
| Width || Number || Width in document units | | Width || Number || Width in document units || FieldDim_Width | ||
|- | |- | ||
| Glazing Area || Number || Glazing area in document units | | Glazing Area || Number || Glazing area in document units || FieldDim_GlazingArea | ||
|- | |- | ||
| Glazing Length || Number || Glazing length in document units | | Glazing Length || Number || Glazing length in document units || FieldDim_GlazingLength | ||
|- | |- | ||
| Frame Length || Number || Frame length in document units | | Frame Length || Number || Frame length in document units || FieldDim_FrameLength | ||
|- | |- | ||
| Light Transmission Glazing || Number || | | Light Transmission Glazing || Number || || FieldReal_LightTrasmGlazing | ||
|- | |- | ||
| General Shading || Number || Shading values:<br/> | | General Shading || Number || Shading values:<br/> | ||
Line 164: | Line 162: | ||
-2 - Medium<br/> | -2 - Medium<br/> | ||
-3 - High<br/> | -3 - High<br/> | ||
X - Custom Value as Specified<br/> | X - Custom Value as Specified<br/> || FieldReal_ShadingGeneral | ||
|- | |- | ||
| Surrounding Shading || Number || Same values as general shading | | Surrounding Shading || Number || Same values as general shading || FieldReal_ShadingSurrounding | ||
|- | |- | ||
| Summer Shading || Number || Same values as general shading | | Summer Shading || Number || Same values as general shading || FieldReal_ShadingSummer | ||
|- | |- | ||
| Additional Shading || Number || Same values as general shading | | Additional Shading || Number || Same values as general shading || FieldReal_ShadingAdditional | ||
|} | |} | ||
'''Note:''' strings are localizable via 'FormatDef_WinDoor.vwstrings' of the EnergyAnalysis.vwr | '''Note:''' strings are localizable via 'FormatDef_WinDoor.vwstrings' of the EnergyAnalysis.vwr | ||
Line 186: | Line 184: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Field name !! Unit !! Description | ! Field name !! Unit !! Description !! .vwstring key | ||
|- | |- | ||
| Sort Index || Integer || Index used to order the elements | | Sort Index || Integer || Index used to order the elements || FieldInt_SortIndex | ||
|- | |- | ||
| Name || Text || | | Name || Text || || FieldText_Name | ||
|- | |- | ||
| Area || Number || Area value in document units | | Area || Number || Area value in document units || FieldDim_Area | ||
|- | |- | ||
| UValue || Number || U - value in document units | | UValue || Number || U - value in document units || FieldReal_UValue | ||
|- | |- | ||
| Orientation || Integer || Orientation values:<br/> | | Orientation || Integer || Orientation values:<br/> | ||
Line 205: | Line 203: | ||
6 - West<br/> | 6 - West<br/> | ||
7 - NorthWest<br/> | 7 - NorthWest<br/> | ||
8 - Horizontal<br/> | 8 - Horizontal<br/> || FieldInt_Orientation | ||
|- | |- | ||
| Inclination || Integer || Orientation inclination degrees:<br/> | | Inclination || Integer || Orientation inclination degrees:<br/> | ||
Line 219: | Line 217: | ||
9 = 150<br/> | 9 = 150<br/> | ||
10 = 165<br/> | 10 = 165<br/> | ||
11 = 180 - Horizontal<br/> | 11 = 180 - Horizontal<br/> || FieldInt_OrientInclination | ||
|- | |- | ||
| Width || Number || Width in document units | | Width || Number || Width in document units || FieldDim_Width | ||
|- | |- | ||
| Glazing Area || Number || Glazing area in document units | | Glazing Area || Number || Glazing area in document units || FieldDim_GlazingArea | ||
|- | |- | ||
| Glazing Length || Number || Glazing length in document units | | Glazing Length || Number || Glazing length in document units || FieldDim_GlazingLength | ||
|- | |- | ||
| Frame Length || Number || Frame length in document units | | Frame Length || Number || Frame length in document units || FieldDim_FrameLength | ||
|- | |- | ||
| Light Transmission Glazing || Number || | | Light Transmission Glazing || Number || || FieldReal_LightTrasmGlazing | ||
|- | |- | ||
| General Shading || Number || Shading values:<br/> | | General Shading || Number || Shading values:<br/> | ||
Line 236: | Line 234: | ||
-2 - Medium<br/> | -2 - Medium<br/> | ||
-3 - High<br/> | -3 - High<br/> | ||
X - Custom Value as Specified<br/> | X - Custom Value as Specified<br/> || FieldReal_ShadingGeneral | ||
|- | |- | ||
| Surrounding Shading || Number || Same values as general shading | | Surrounding Shading || Number || Same values as general shading || FieldReal_ShadingSurrounding | ||
|- | |- | ||
| Summer Shading || Number || Same values as general shading | | Summer Shading || Number || Same values as general shading || FieldReal_ShadingSummer | ||
|- | |- | ||
| Additional Shading || Number || Same values as general shading | | Additional Shading || Number || Same values as general shading || FieldReal_ShadingAdditional | ||
|} | |} | ||
'''Note:''' strings are localizable via 'FormatDef_WinDoor.vwstrings' of the EnergyAnalysis.vwr | '''Note:''' strings are localizable via 'FormatDef_WinDoor.vwstrings' of the EnergyAnalysis.vwr | ||
Line 258: | Line 256: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Field name !! Unit !! Description | ! Field name !! Unit !! Description !! .vwstring key | ||
|- | |- | ||
| Name || Text || | | Name || Text || || FieldText_Name | ||
|- | |- | ||
| Area || Number || Area value in document units | | Area || Number || Area value in document units || FieldDim_Area | ||
|- | |- | ||
| Volume || Number || Volume value in document units | | Volume || Number || Volume value in document units || FieldDim_Volume | ||
|- | |- | ||
| Orientation || Integer || Orientation values:<br/> | | Orientation || Integer || Orientation values:<br/> | ||
Line 275: | Line 273: | ||
6 - West<br/> | 6 - West<br/> | ||
7 - NorthWest<br/> | 7 - NorthWest<br/> | ||
8 - Horizontal<br/> | 8 - Horizontal<br/> || FieldInt_Orientation | ||
|- | |- | ||
| Width || Number || Width in document units | | Width || Number || Width in document units || FieldDim_Width | ||
|- | |- | ||
| Depth || Number || Depth in document units | | Depth || Number || Depth in document units || FieldDim_Depth | ||
|- | |- | ||
| Height || Number || Height in document units | | Height || Number || Height in document units || FieldDim_Height | ||
|- | |- | ||
| Lintel Height || Number || Height in document units | | Lintel Height || Number || Height in document units || FieldDim_LintelHeight | ||
|- | |- | ||
| Window Width || Number || Width in document units | | Window Width || Number || Width in document units || FieldDim_WindowWidth | ||
|- | |- | ||
| Light Transmission Glazing Percent || Number || || | | Light Transmission Glazing Percent || Number || || || FieldReal_LightTransmissionGlazingPercent | ||
|- | |- | ||
| Lighting Full Load Hours || Number || h/a | | Lighting Full Load Hours || Number || h/a || FieldReal_LightingFullLoadHours | ||
|- | |- | ||
| Installer Light Power || Number || Document unit for W/m2 | | Installer Light Power || Number || Document unit for W/m2 || FieldReal_InstalledLightPower | ||
|- | |- | ||
| Lighting Control || Integer || Lighting Control Values:<br/> | | Lighting Control || Integer || Lighting Control Values:<br/> | ||
Line 297: | Line 295: | ||
1 - WithoutOffMode<br/> | 1 - WithoutOffMode<br/> | ||
2 - WithOffMode<br/> | 2 - WithOffMode<br/> | ||
3 - BusSystem<br/> | 3 - BusSystem<br/> || FieldInt_LightingControl | ||
|- | |- | ||
| Motion Detector || Boolean || | | Motion Detector || Boolean || || FieldBool_MotionDetector | ||
|- | |- | ||
| Extract Air Room Type || Integer || Extract Air Room Type Value:<br/> | | Extract Air Room Type || Integer || Extract Air Room Type Value:<br/> | ||
Line 306: | Line 304: | ||
2 - Shower<br/> | 2 - Shower<br/> | ||
3 - WC<br/> | 3 - WC<br/> | ||
4 - Other<br/> | 4 - Other<br/> || FieldInt_ExtractAirRoomType | ||
|- | |- | ||
| Extract Air Requirement Volume || Number || Document volume/h | | Extract Air Requirement Volume || Number || Document volume/h || FieldDim_ExtractAirRequirement | ||
|} | |} | ||
'''Note:''' strings are localizable via 'FormatDef_Space.vwstrings' of the EnergyAnalysis.vwr | '''Note:''' strings are localizable via 'FormatDef_Space.vwstrings' of the EnergyAnalysis.vwr | ||
Line 325: | Line 323: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Field name !! Unit !! Description | ! Field name !! Unit !! Description !! .vwstring key | ||
|- | |- | ||
| Sort Index || Integer || Index used to order the elements | | Sort Index || Integer || Index used to order the elements || FieldInt_SortIndex | ||
|- | |- | ||
| Name || Text || | | Name || Text || || FieldText_Name | ||
|- | |- | ||
| Area || Number || Area value in document units | | Area || Number || Area value in document units || FieldDim_Area | ||
|- | |- | ||
| UValue || Number || U - value in document units | | UValue || Number || U - value in document units || FieldReal_UValue | ||
|- | |- | ||
| Orientation || Integer || Orientation values:<br/> | | Orientation || Integer || Orientation values:<br/> | ||
Line 344: | Line 342: | ||
6 - West<br/> | 6 - West<br/> | ||
7 - NorthWest<br/> | 7 - NorthWest<br/> | ||
8 - Horizontal<br/> | 8 - Horizontal<br/> || FieldInt_Orientation | ||
|- | |- | ||
| Inclination || Integer || Orientation inclination degrees:<br/> | | Inclination || Integer || Orientation inclination degrees:<br/> | ||
Line 358: | Line 356: | ||
9 = 150<br/> | 9 = 150<br/> | ||
10 = 165<br/> | 10 = 165<br/> | ||
11 = 180 - Horizontal<br/> | 11 = 180 - Horizontal<br/> || FieldInt_OrientInclination | ||
|- | |- | ||
| RS Internal || Number || | | RS Internal || Number || || FieldReal_RSInternal | ||
|- | |- | ||
| RS External || Number || | | RS External || Number || || FieldReal_RSExternal | ||
|- | |- | ||
| Exposed Perimeter To Open || Number || | | Exposed Perimeter To Open || Number || || FieldReal_ExposedPerimToOpen | ||
|} | |} | ||
Note: strings are localizable via 'FormatDef_Slab.vwstrings' of the EnergyAnalysis.vwr | Note: strings are localizable via 'FormatDef_Slab.vwstrings' of the EnergyAnalysis.vwr | ||
=== Roof === | === Roof === | ||
Line 432: | Line 375: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Field name !! Unit !! Description | ! Field name !! Unit !! Description !! .vwstring key | ||
|- | |- | ||
| | | Sort Index || Integer || Index used to order the elements || FieldInt_SortIndex | ||
|- | |- | ||
| | | Name || Text || || FieldText_Name | ||
|- | |- | ||
| | | Area || Number || Area value in document units || FieldDim_Area | ||
|- | |- | ||
| | | UValue || Number || U - value in document units || FieldReal_UValue | ||
|- | |- | ||
| Orientation || Integer || values:<br/> | | Orientation || Integer || values:<br/> | ||
Line 453: | Line 394: | ||
6 - West<br/> | 6 - West<br/> | ||
7 - NorthWest<br/> | 7 - NorthWest<br/> | ||
8 - Horizontal<br/> | 8 - Horizontal<br/> || FieldInt_Orientation | ||
|- | |- | ||
| Inclination || Integer || Orientation inclination degrees:<br/> | | Inclination || Integer || Orientation inclination degrees:<br/> | ||
Line 467: | Line 408: | ||
9 = 150<br/> | 9 = 150<br/> | ||
10 = 165<br/> | 10 = 165<br/> | ||
11 = 180 - Horizontal | 11 = 180 - Horizontal || FieldInt_OrientInclination | ||
|- | |- | ||
| Reduction Factor Shading || Number || | | Reduction Factor Shading || Number || || FieldReal_ReductionFactorShading | ||
|} | |} | ||
Revision as of 16:03, 23 March 2016
.VectorScript|VectorScript ..VS:Function Reference|Function Reference ..VS:Function_Reference_Appendix|Appendix
Records can be attached to any object to define energy analysis data to be used. Depending on the record the object is identified and used as the corresponding energy analysis element.
Note that these records/formats don't define the full set of properties. They are designed for simplicity to allow any Vectorworks object to be setup to participate in the energy analysis.
if you are integrating custom parametric objects with the energy analysis feature see:
Here is the definition of the formats that are recognized by the feature (all noted units are units defined by the energy analysis units settings):
Formats
Note: that all the format names and fields are localized. This means that in localized versions of Vectorworks, they will be in the corresponding language. Note the information of how to read the resource containing the localized strings, or look at the scripts below.
Wall
Attach a record of this format to define the energy properties of a wall
Format name: Energos Wall
Field name | Unit | Description | .vwstring key |
---|---|---|---|
Sort Index | Integer | Index used to order the elements | FieldInt_SortIndex |
Name | Text | FieldText_Name | |
Area | Number | Area value in document units | FieldDim_Area |
UValue | Number | U - value in document units | FieldReal_UValue |
Orientation | Integer | Orientation values: 0 - North | |
Inclination | Integer | Orientation inclination degrees: 0 = 0 - Horizontal | |
Reduction Factor Shading | Number | FieldReal_ReductionFactorShading | |
Wall Type | Integer | 0 - Exterior Ambient |
Note: strings are localizable via 'FormatDef_Wall.vwstrings' of the EnergyAnalysis.vwr
Thermal Bridge
Attach a record of this format to define the energy properties of a thermal-bridge
Format name: Energos Thermal Bridge
Field name | Unit | Description | .vwstring key |
---|---|---|---|
Sort Index | Integer | Index used to order the elements | FieldInt_SortIndex |
Name | Text | FieldText_Name | |
Quantity | Integer | FieldLong_Quantity | |
Location | Integer | Location values: 0 - None | |
Length | Number | thermal bridge length in document units | FieldDim_Length |
PSI | Number | FieldReal_PSI |
Note: strings are localizable via 'FormatDef_ThermalBridge.vwstrings' of the EnergyAnalysis.vwr
Window
Attach a record of this format to define the energy properties of a window
Format name: Energos Window
Field name | Unit | Description | .vwstring key |
---|---|---|---|
Sort Index | Integer | Index used to order the elements | FieldInt_SortIndex |
Name | Text | FieldText_Name | |
Area | Number | Area value in document units | FieldDim_Area |
UValue | Number | U - value in document units | FieldReal_UValue |
Orientation | Integer | Orientation values: 0 - North | |
Inclination | Integer | Orientation inclination degrees: 0 = 0 - Horizontal | |
Width | Number | Width in document units | FieldDim_Width |
Glazing Area | Number | Glazing area in document units | FieldDim_GlazingArea |
Glazing Length | Number | Glazing length in document units | FieldDim_GlazingLength |
Frame Length | Number | Frame length in document units | FieldDim_FrameLength |
Light Transmission Glazing | Number | FieldReal_LightTrasmGlazing | |
General Shading | Number | Shading values: 0 - None | |
Surrounding Shading | Number | Same values as general shading | FieldReal_ShadingSurrounding |
Summer Shading | Number | Same values as general shading | FieldReal_ShadingSummer |
Additional Shading | Number | Same values as general shading | FieldReal_ShadingAdditional |
Note: strings are localizable via 'FormatDef_WinDoor.vwstrings' of the EnergyAnalysis.vwr
Door
Attach a record of this format to define the energy properties of a door
Format name: Energos Door
Field name | Unit | Description | .vwstring key |
---|---|---|---|
Sort Index | Integer | Index used to order the elements | FieldInt_SortIndex |
Name | Text | FieldText_Name | |
Area | Number | Area value in document units | FieldDim_Area |
UValue | Number | U - value in document units | FieldReal_UValue |
Orientation | Integer | Orientation values: 0 - North | |
Inclination | Integer | Orientation inclination degrees: 0 = 0 - Horizontal | |
Width | Number | Width in document units | FieldDim_Width |
Glazing Area | Number | Glazing area in document units | FieldDim_GlazingArea |
Glazing Length | Number | Glazing length in document units | FieldDim_GlazingLength |
Frame Length | Number | Frame length in document units | FieldDim_FrameLength |
Light Transmission Glazing | Number | FieldReal_LightTrasmGlazing | |
General Shading | Number | Shading values: 0 - None | |
Surrounding Shading | Number | Same values as general shading | FieldReal_ShadingSurrounding |
Summer Shading | Number | Same values as general shading | FieldReal_ShadingSummer |
Additional Shading | Number | Same values as general shading | FieldReal_ShadingAdditional |
Note: strings are localizable via 'FormatDef_WinDoor.vwstrings' of the EnergyAnalysis.vwr
Space
Attach a record of this format to define the energy properties of a space
Format name: Energos Space
Field name | Unit | Description | .vwstring key | |
---|---|---|---|---|
Name | Text | FieldText_Name | ||
Area | Number | Area value in document units | FieldDim_Area | |
Volume | Number | Volume value in document units | FieldDim_Volume | |
Orientation | Integer | Orientation values: 0 - North | ||
Width | Number | Width in document units | FieldDim_Width | |
Depth | Number | Depth in document units | FieldDim_Depth | |
Height | Number | Height in document units | FieldDim_Height | |
Lintel Height | Number | Height in document units | FieldDim_LintelHeight | |
Window Width | Number | Width in document units | FieldDim_WindowWidth | |
Light Transmission Glazing Percent | Number | FieldReal_LightTransmissionGlazingPercent | ||
Lighting Full Load Hours | Number | h/a | FieldReal_LightingFullLoadHours | |
Installer Light Power | Number | Document unit for W/m2 | FieldReal_InstalledLightPower | |
Lighting Control | Integer | Lighting Control Values: 0 - Manual | ||
Motion Detector | Boolean | FieldBool_MotionDetector | ||
Extract Air Room Type | Integer | Extract Air Room Type Value: 0 - Kitchen | ||
Extract Air Requirement Volume | Number | Document volume/h | FieldDim_ExtractAirRequirement |
Note: strings are localizable via 'FormatDef_Space.vwstrings' of the EnergyAnalysis.vwr
Slab
Attach a record of this format to define the energy properties of a slab
Format name: Energos Slab
Field name | Unit | Description | .vwstring key |
---|---|---|---|
Sort Index | Integer | Index used to order the elements | FieldInt_SortIndex |
Name | Text | FieldText_Name | |
Area | Number | Area value in document units | FieldDim_Area |
UValue | Number | U - value in document units | FieldReal_UValue |
Orientation | Integer | Orientation values: 0 - North | |
Inclination | Integer | Orientation inclination degrees: 0 = 0 - Horizontal | |
RS Internal | Number | FieldReal_RSInternal | |
RS External | Number | FieldReal_RSExternal | |
Exposed Perimeter To Open | Number | FieldReal_ExposedPerimToOpen |
Note: strings are localizable via 'FormatDef_Slab.vwstrings' of the EnergyAnalysis.vwr
Roof
Attach a record of this format to define the energy properties of a roof
Format name: Energos Roof
Field name | Unit | Description | .vwstring key |
---|---|---|---|
Sort Index | Integer | Index used to order the elements | FieldInt_SortIndex |
Name | Text | FieldText_Name | |
Area | Number | Area value in document units | FieldDim_Area |
UValue | Number | U - value in document units | FieldReal_UValue |
Orientation | Integer | values: 0 - North | |
Inclination | Integer | Orientation inclination degrees: 0 = 0 - Horizontal | |
Reduction Factor Shading | Number | FieldReal_ReductionFactorShading |
Note: strings are localizable via 'FormatDef_Roof.vwstrings' of the EnergyAnalysis.vwr
Example Scripts - Python Script
You can use the following scripts to create the formats:
Wall
# Energos Thermal Bridge vwr = 'EnergyAnalysis/Strings/FormatDef_Wall.vwstrings' formatName = vs.GetVWRString(vwr, 'FormatName' ) vs.NewField(formatName, vs.GetVWRString(vwr, "FieldInt_SortIndex" ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, "FieldText_Name" ), '', 4, 0 ) #text vs.NewField(formatName, vs.GetVWRString(vwr, "FieldDim_Area" ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, "FieldReal_UValue" ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, "FieldInt_Orientation" ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, "FieldInt_OrientInclination" ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, "FieldReal_ReductionFactorShading"), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, "FieldInt_WallType" ), '0', 1, 0 ) #int
Thermal Bridge
# Energos Thermal Bridge vwr = 'EnergyAnalysis/Strings/FormatDef_ThermalBridge.vwstrings' formatName = vs.GetVWRString(vwr, 'FormatName' ) vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_SortIndex'), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldText_Name' ), '', 4, 0 ) #text vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldLong_Quantity'), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldLong_Location'), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Length' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_PSI' ), '0', 3, 0 ) #real
Window
# Energos Window vwr = 'EnergyAnalysis/Strings/FormatDef_WinDoor.vwstrings' formatName = vs.GetVWRString(vwr, 'FormatNameWindow' ) vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_SortIndex' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldText_Name' ), '', 4, 0 ) #text vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Area' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_UValue' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_Orientation' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_OrientInclination' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Width' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_GlazingArea' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_GlazingLength' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_FrameLength' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_LightTrasmGlazing' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingGeneral' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingSurrounding'), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingSummer' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingAdditional' ), '0', 3, 0 ) #real
Door
# Energos Door vwr = 'EnergyAnalysis/Strings/FormatDef_WinDoor.vwstrings' formatName = vs.GetVWRString(vwr, 'FormatNameDoor' ) vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_SortIndex' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldText_Name' ), '', 4, 0 ) #text vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Area' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_UValue' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_Orientation' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_OrientInclination' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Width' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_GlazingArea' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_GlazingLength' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_FrameLength' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_LightTrasmGlazing' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingGeneral' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingSurrounding'), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingSummer' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ShadingAdditional' ), '0', 3, 0 ) #real
Space
# Energos Space vwr = 'EnergyAnalysis/Strings/FormatDef_Space.vwstrings' formatName = vs.GetVWRString(vwr, 'FormatName' ) vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldText_Name' ), '', 4, 0 ) #text vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Area' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Volume' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_Orientation' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Width' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Depth' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Height' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_LintelHeight' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_WindowWidth' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_LightTransmissionGlazingPercent'), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_LightingFullLoadHours' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_InstalledLightPower' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_LightingControl' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldBool_MotionDetector' ), '0', 2, 0 ) #bool vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_ExtractAirRoomType' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_ExtractAirRequirement' ), '0', 3, 0 ) #real
Slab
# Energos Slab vwr = 'EnergyAnalysis/Strings/FormatDef_Slab.vwstrings' formatName = vs.GetVWRString(vwr, 'FormatName' ) vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_SortIndex' ), '0', 1, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldText_Name' ), '', 4, 0 ) #text vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Area' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_UValue' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_Orientation' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_OrientInclination' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_RSInternal' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_RSExternal' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ExposedPerimToOpen'), '0', 3, 0 ) #real
Roof
# Energos Roof vwr = 'EnergyAnalysis/Strings/FormatDef_Roof.vwstrings' formatName = vs.GetVWRString(vwr, 'FormatName' ) vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_SortIndex' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldText_Name' ), '', 4, 0 ) #text vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldDim_Area' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_UValue' ), '0', 3, 0 ) #real vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_Orientation' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldInt_OrientInclination' ), '0', 1, 0 ) #int vs.NewField(formatName, vs.GetVWRString(vwr, 'FieldReal_ReductionFactorShading'), '0', 3, 0 ) #real